1.
Marin-Neto, José Antonio; Rassi Jr, Anis; Oliveira, Gláucia Maria Moraes; Correia, Luís Claudio Lemos; Ramos Júnior, Alberto Novaes; Luquetti, Alejandro Ostermayer; Hasslocher-Moreno, Alejandro Marcel; Sousa, Andréa Silvestre de; Paola, Angelo Amato Vincenzo de; Sousa, Antônio Carlos Sobral; Ribeiro, Antonio Luiz Pinho; Correia Filho, Dalmo; Souza, Dilma do Socorro Moraes de; Cunha-Neto, Edecio; Ramires, Felix Jose Alvarez; Bacal, Fernando; Nunes, Maria do Carmo Pereira; Martinelli Filho, Martino; Scanavacca, Maurício Ibrahim; Saraiva, Roberto Magalhães; Oliveira Júnior, Wilson Alves de; Lorga-Filho, Adalberto Menezes; Guimarães, Adriana de Jesus Benevides de Almeida; Braga, Adriana Lopes Latado; Oliveira, Adriana Sarmento de; Sarabanda, Alvaro Valentim Lima; Pinto, Ana Yecê das Neves; Carmo, Andre Assis Lopes do; Schmidt, Andre; Costa, Andréa Rodrigues da; Ianni, Barbara Maria; Markman Filho, Brivaldo; Rochitte, Carlos Eduardo; Macêdo, Carolina Thé; Mady, Charles; Chevillard, Christophe; Virgens, Cláudio Marcelo Bittencourt das; Castro, Cleudson Nery de; Britto, Constança Felicia De Paoli de Carvalho; Pisani, Cristiano; Rassi, Daniela do Carmo; Sobral Filho, Dário Celestino; Almeida, Dirceu Rodrigues de; Bocchi, Edimar Alcides; Mesquita, Evandro Tinoco; Mendes, Fernanda de Souza Nogueira Sardinha; Gondim, Francisca Tatiana Pereira; Silva, Gilberto Marcelo Sperandio da; Peixoto, Giselle de Lima; Lima, Gustavo Glotz de; Veloso, Henrique Horta; Moreira, Henrique Turin; Lopes, Hugo Bellotti; Pinto, Ibraim Masciarelli Francisco; Ferreira, João Marcos Bemfica Barbosa; Nunes, João Paulo Silva; Barreto-Filho, José Augusto Soares; Saraiva, José Francisco Kerr; Lannes-Vieira, Joseli; Oliveira, Joselina Luzia Menezes; Armaganijan, Luciana Vidal; Martins, Luiz Cláudio; Sangenis, Luiz Henrique Conde; Barbosa, Marco Paulo Tomaz; Almeida-Santos, Marcos Antonio; Simões, Marcos Vinicius; Yasuda, Maria Aparecida Shikanai; Moreira, Maria da Consolação Vieira; Higuchi, Maria de Lourdes; Monteiro, Maria Rita de Cassia Costa; Mediano, Mauro Felippe Felix; Lima, Mayara Maia; Oliveira, Maykon Tavares de; Romano, Minna Moreira Dias; Araujo, Nadjar Nitz Silva Lociks de; Medeiros, Paulo de Tarso Jorge; Alves, Renato Vieira; Teixeira, Ricardo Alkmim; Pedrosa, Roberto Coury; Aras Junior, Roque; Torres, Rosalia Morais; Povoa, Rui Manoel dos Santos; Rassi, Sergio Gabriel; Alves, Silvia Marinho Martins; Tavares, Suelene Brito do Nascimento; Palmeira, Swamy Lima; Silva Júnior, Telêmaco Luiz da; Rodrigues, Thiago da Rocha; Madrini Junior, Vagner; Brant, Veruska Maia da Costa; Dutra, Walderez Ornelas; Dias, João Carlos Pinto.
Arq. bras. cardiol ; 120(6): e20230269, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1447291
6.
Arq. bras. cardiol ; 109(1): 14-22, July 2017. tab
Artigo em Inglês | LILACS | ID: biblio-887900

RESUMO

Abstract Background: Cox-Maze III procedure is one of the surgical techniques used in the surgical treatment of atrial fibrillation (AF). Objectives: To determine late results of Cox-Maze III in terms of maintenance of sinus rhythm, and mortality and stroke rates. Methods: Between January 2006 and January 2013, 93 patients were submitted to the cut-and-sew Cox-Maze III procedure in combination with structural heart disease repair. Heart rhythm was determined by 24-hour Holter monitoring. Procedural success rates were determined by longitudinal methods and recurrence predictors by multivariate Cox regression models. Results: Thirteen patients that obtained hospital discharge alive were excluded due to lost follow-up. The remaining 80 patients were aged 49.9 ± 12 years and 47 (58.7%) of them were female. Involvement of mitral valve and rheumatic heart disease were found in 67 (83.7%) and 63 (78.7%) patients, respectively. Seventy patients (87.5%) had persistent or long-standing persistent AF. Mean follow-up with Holter monitoring was 27.5 months. There were no hospital deaths. Sinus rhythm maintenance rates were 88%, 85.1% and 80.6% at 6 months, 24 months and 36 months, respectively. Predictors of late recurrence of AF were female gender (HR 3.52; 95% CI 1.21-10.25; p = 0.02), coronary artery disease (HR 4.73 95% CI 1.37-16.36; p = 0.01) and greater left atrium diameter (HR 1.05; 95% CI 1.01-1.09; p = 0.02). Actuarial survival was 98.5% at 12, 24 and 48 months and actuarial freedom from stroke was 100%, 100% and 97.5% in the same time frames. Conclusions: The Cox-Maze III procedure, in our experience, is efficacious for sinus rhythm maintenance, with very low late mortality and stroke rates.


Resumo Fundamento: A operação de Cox-Maze III é uma das variantes técnicas no tratamento cirúrgico da fibrilação atrial (FA). Objetivos: Estudar os resultados tardios da operação de Cox-Maze III, quanto à eficácia na manutenção de ritmo sinusal e taxas de mortalidade e acidente vascular cerebral (AVC). Métodos: Entre janeiro de 2006 a janeiro de 2013, 93 pacientes foram submetidos a operação de Cox-Maze III por corte e sutura associada a correção de cardiopatias estruturais. Avaliação do ritmo cardíaco ocorreu por Holter 24 horas. Taxas de sucesso da operação foram estudadas por métodos longitudinais e os preditores de recorrência por análise de regressão de Cox multivariada. Resultados: Foram excluídos 13 pacientes sobreviventes ao período intra-hospitalar cujo seguimento tardio não foi possível. Os 80 pacientes restantes tinham idade média de 49,9 ± 12 anos e 47 (58,75%) eram do sexo feminino. Acometimento da valva mitral ocorreu em 67 pacientes (83,7%). Valvopatia reumática ocorreu em 63 (78,7%). Setenta pacientes (87,5%) tinham fibrilação atrial persistente ou persistente de longa duração. O tempo médio de seguimento clínico com avaliação de Holter foi de 27,5 meses. Não houve óbitos intra-hospitalares. As taxas de manutenção de ritmo sinusal foram 88%, 85,1% e 80,6% aos 6 meses, 24 meses e 36 meses, respectivamente. Os preditores de recorrência tardia foram sexo feminino (RR 3,52; IC 95% 1,21-10,25; p = 0,02), doença arterial coronária (RR 4,73; IC 95% 1,37-16,36; p = 0,01) e maior diâmetro de átrio esquerdo (RR 1,05; IC 95% 1,01-1,09; p = 0,02). A sobrevida atuarial aos 12, 24 e 48 meses foi de 98,5% e as taxas atuariais livres de AVC nos mesmos períodos de 100%, 100% e 97,5%. Conclusões: A operação de Cox-Maze III, na nossa experiência, é eficaz na manutenção do ritmo sinusal, com baixíssimos índices de mortalidade e de AVC tardios.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/etiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Recidiva , Fibrilação Atrial/etiologia , Fibrilação Atrial/mortalidade , Fatores de Tempo , Taxa de Sobrevida , Fatores de Risco , Estudos de Coortes , Resultado do Tratamento
7.
Rev. bras. ecocardiogr. imagem cardiovasc ; 23(4): 75-85, out.-dez. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-562265

RESUMO

A terapia de ressincronização cardíaca (TRC) estabeleceu-se na última década, como uma nova estratégia de tratamento de pacientes com insuficiência cardíaca refratária ao tratamento clínico. Entretanto, cerca de 20 a 30% dos pacientes não são responsivos à TRC, o que enfatiza a necessidade de se empenhar melhores critérios para a seleção de pacientes. Diversos estudos clínicos demonstraram resultados mais favoráveis à TRC, quando os pacientes apresentavam dissincronia mecânica do VE à ecocardiografia. No entanto, o resultado do principal estudo multicêntrico prospect demonstrou somente uma modesta acurácia dos parâmetros ecocardiográficos de dissincronia do VE, na predição à TRC. Esse resultado reforça a noção de que dissincronia mecânica é somente um dos substratos da TRC, e que outros fatores, tais como a viabilidade miocárdica e a presença de cicatriz transmural, na região em que usualmente realiza-se a estimulação do VE, são fatores relevantes no sucesso desse tratamento. Nesta revisão, realizou-se, uma avaliação geral sobre a TRC e discutiu-se os principais métodos de avaliação de dissincronia ao ecocardiograma e ressonância magnética, sua aplicação na prática clínica atual e as perspectivas futuras.


Assuntos
Humanos , Ecocardiografia/métodos , Ecocardiografia , Espectroscopia de Ressonância Magnética/uso terapêutico , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico
8.
Arq. bras. cardiol ; 94(1): e7-e10, jan. 2010. ilus
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-543876

RESUMO

Neste relato de caso, descrevemos um paciente portador de fibrilação atrial (FA) persistente, submetido à ablação percutânea da FA pela técnica de isolamento extraostial das veias pulmonares, que desenvolveu uma estenose acentuada do óstio da veia pulmonar superior esquerda (VPSE), sem manifestar sintomas, diagnosticada pela angiotomografia de controle das veias pulmonares. O paciente foi submetido à angioplastia com implante de stent na VPSE com sucesso, resultando na normalização da perfusão pulmonar, verificado pela cintilografia pulmonar realizada 3 meses após a angioplastia.


This case report describes a patient with persistent atrial fibrillation (AF) submitted to radiofrequency catheter ablation of AF through the pulmonary vein antrum isolation technique, who developed a severe stenosis of the left superior pulmonary vein (LSPV), without presenting any symptoms. The diagnosis of the PV stenosis was made by a routine postprocedure computed tomography scan of the left atrium, and the patient was subsequently submitted to angioplasty with stenting of the LSPV, resulting in the normalization of pulmonary perfusion, as seen by ventilation/perfusion scan made three months after the LSPV angioplasty.


En este caso clínico, describimos a un paciente portador de fibrilación atrial (FA) persistente, sometido a ablación percutánea de la FA por la técnica de aislamiento extraostial de las venas pulmonares, que desarrolló una estenosis acentuada del ostio de la vena pulmonar superior izquierda (VPSI), sin manifestar síntomas, diagnosticada por la angiotomografía de control de las venas pulmonares. El paciente se sometió a angioplastia con implante de stent en la VPSI con éxito, resultando en la normalización de la perfusión pulmonar, verificado por el centellograma pulmonar realizada 3 meses tras la angioplastia.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Pneumopatia Veno-Oclusiva/etiologia , Cuidados Pós-Operatórios/normas , Pneumopatia Veno-Oclusiva/patologia
9.
Arq. bras. cardiol ; 93(6): 666-671, dez. 2009. ilus
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-542750

RESUMO

Fundamento: O isolamento das veias pulmonares (IVP) tem sido usado como endpoint para a ablação da fibrilação atrial (FA) com cateter balão. Objetivo: Determinar a utilidade do ultrassom intracardíaco (USIC) para guiar o IVP, usando cateter balão a laser. Métodos: 59 VP foram ablacionadas em 27 cães. Imagens de Doppler foram usadas para identificar os vazamentos do fluxo sanguíneo entre a VP e o balão. Após cada liberação de energia, o cateter de mapeamento circular foi reposicionado para verificar se o isolamento tinha sido obtido. A posição de vazamento foi então correlacionada com a posição do gap no estudo patológico. A análise de regressão logística multivariada foi realizada. Resultados: Cinquenta e nove VP foram submetidas à ablação. O tempo médio de energia liberada foi de 279±177 seg., o diâmetro médio do balão era de 23±3 mm, e o comprimento médio do balão era 25±4 mm. O isolamento completo foi obtido em 38/59 (64 por cento), e foi significantemente mais comum sem vazamento: [30/38 (79 por cento) versus 8/23 (35 por cento), p<0,001]. Isso foi independente do tempo de aplicação (302±223 seg. vs. 266±148 sec., p=ns), potência (3,5 W/cm, 4,5 W/cm, e 5,5 W/cm), diâmetro do balão (24± 3 mm vs. 22± 3 mm, p= ns) e comprimento (27±4 mm vs. 24±4 mm, p=ns). O valor preditivo positivo para previsão de isolamento completo foi de 65 por cento e o valor preditivo negativo foi 83 por cento. Conclusão: Um vazamento identificável entre a VP e o dispositivo de ablação por cateter-balão observado no USIC é preditor de menor taxa de isolamento de VP mais baixas. O USIC pode ser útil para detectar vazamentos a fim de evitar o uso ineficaz de aplicação energia durante a ablação circunferencial da VP. Isto também pode ser útil quando outras energias são utilizadas.


Background: Pulmonary vein isolation (PVI) with balloon catheter has been used as the endpoint for AF ablation. Objective: To determine the usefulness of intracardiac ultrasound (ICUS) to guide PVI using laser balloon catheter. Methods: 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken. Results: 59 PV were ablated. Mean burn time was 279±177 sec, mean balloon diameter was 23±3 mm, and mean balloon length was 25±4 mm. Complete isolation was achieved in 38/59 (64 percent) cases, and it was significantly more common when there was no leak: [30/38 (79 percent) versus 8/23 (35 percent), p<0.001]. This occurred regardless of time of laser application (302±223 sec. vs. 266±148 sec., p=ns), laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm), balloon diameter (24± 3 mm vs. 22± 3 mm, p=ns) and length (27±4 mm vs. 24±4mm, p=ns). The positive predictive value for predicting incomplete isolation was 65 percent and the negative predictive value was 83 percent. Conclusion: An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.


Fundamento: Se usó el aislamiento de las venas pulmonares (AVP) como endpoint para la ablación de la fibrilación atrial (FA) con catéter-balón. Objetivo: Determinar la utilidad del ultrasonido intracardíaco (USIC) para guiar el AVP, usando catéter-balón láser. Métodos: Se ablacionaron 59 VP en 27 perros. Se usaron imágenes de Doppler para identificar los derrames del flujo sanguíneo entre la VP y el balón. Tras cada liberación de energía, se reposicionó el catéter de mapeamiento circular para verificar si se obtuvo el aislamiento. Se correlaccionó, entonces, la posición del derrame con la posición del gap en el estudio patológico. Se realizó el análisis de regresión logística multivariada. Resultados: Se sometieron 59 VP a la ablación. El tiempo promedio de energía liberada fue de 279±177 seg., el diámetro promedio del balón era de 23±3 mm, y la largura promedio del balón era 25±4 mm. Se obtuvo el aislamiento completo en 38/59 (64 por ciento), y fue significantemente más común sin derrame: [30/38 (79 por ciento) versus 8/23 (35 por ciento), p<0,001]. Eso fue independiente del tiempo de aplicación (302±223 seg. vs. 266±148 sec., p=ns), potencia (3,5 W/cm, 4,5 W/cm, y 5,5 W/cm), diámetro del balón (24± 3 mm vs. 22± 3 mm, p= ns) y largura (27±4 mm vs. 24±4 mm, p=ns). El valor predictivo positivo para la previsión del aislamiento completo fue del 65 por ciento y el valor predictivo negativo fue del 83 por ciento. Conclusión: Un derrame identificable entre la VP y el dispositivo de ablación por catéter-balón observado en el USIC es predictor de menor tasa del aislamiento de la VP más baja. El USIC puede ser útil para detectar derrames a fin de evitar el uso ineficaz de la aplicación de la energía durante la ablación circunferencial de la VP. Ello también puede ser útil cuando se utilizan otras energías.


Assuntos
Animais , Cães , Masculino , Ablação por Cateter/métodos , Complicações Intraoperatórias , Lasers/efeitos adversos , Veias Pulmonares/cirurgia , Ultrassonografia de Intervenção , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Métodos Epidemiológicos , Modelos Animais , Veias Pulmonares/lesões , Veias Pulmonares , Ultrassonografia Doppler em Cores/normas
11.
Artigo em Português | LILACS-Express | LILACS, VETINDEX | ID: biblio-1456033

RESUMO

INTRODUCTION: The selection of the surgical approach to the mitral valve is a critical factor in obtaining good exposure and minimizing lesions of the surrounding structures. The classical right lateral subseptal access may sometimes provide difficult exposure, so that alternative approaches are used whose effects on atrial electrical activity are contradictory. OBJECTIVE:To standardize an investigative method to evaluate heart electrical activity post-op. METHODS: Ten consecutive adult patients with mitral valve disease were operated on. Surface electrocardiogram and continuous electrocardiographic monitoring (Holter system) pre and post-op., and epicardical cardioestimulation post-op. were used to study cardiac electric activity. RESULTS: There was no mortality. All patients with sinus rhythm presented supraventricular ectopia, with episodes of supraventricular tachycardia in 57%, atrial flutter in 10%, and junctional rhythm in 10%. All patients presented ventricular ectopia, with a low incidence in 70% of them and with unsustained ventricular tachycardia in 30%. During the postoperative period there was a 40% rate of new supraventricular arrhythmias (atrial fibrillation, junctional rhythm, low atrial rhythm, and paroxistic supraventricular tachycardia), with no ventricular arrhythmias. Post-op. sinus node function was preserved. There was a significant reduction of supraventricular ectopia, with reversal of atrial fibrillation to sinus rhythm in one patient. Although there was a significant reduction in left atrium size post-op, P wave duration, as well as ventricular ectopia rate remained unchanged. Interatrial conduction time correlated with left atrium size measured pre and post-op. CONCLUSION: The methods proved useful to evaluate atrial electric activity in patients operated upon by the classic subseptal access, thus permitting future comparisons with other surgical approaches to the mitral valve.


INTRODUÇÃO: O acesso cirúrgico por esternotomia mediana e atriotomia subseptal clássica pode, em certos casos, resultar em má exposição da valva mitral. Incisões atriais alternativas otimizam a exposição da valva mitral mas podem interferir na atividade elétrica atrial pós-operatória. OBJETIVO: Padronizar método para investigar a atividade elétrica atrial para emprego em estudos comparativos de diferentes atriotomias em cardiopatas sumetidos à cirurgia cardíaca. MÉTODOS: Análise com eletrocardiograma convencional e de 24 h (sistema Holter), pré e pós-operatória, e cardioestimulação epicárdica pós-operatória pelo método de Narula, em 10 pacientes submetidos à correção de valvopatias mitrais. RESULTADOS: No pré-op., os pacientes em ritmo sinusal apresentaram ectopias supraventriculares, com episódios de taquicardia supraventricular em 57% dos casos, "flutter" atrial em 10% e ritmo juncional em 10%. Todos apresentaram ectopias ventriculares, de baixa incidência em 70% dos casos, e taquicardia ventricular não sustentada foi detectada em 30% dos pacientes. No pós-operatório, houve 40% de novas arritmias supraventriculares (fibrilação atrial, ritmo juncional, ritmo atrial baixo e taquicardia supraventricular paroxística), mas não ocorreram arritmias ventriculares. No pós-op. a função do nó sinusal não se alterou, ocorreu redução significativa das ectopias supraventriculares, com reversão de FA para ritmo sinusal em 1 paciente, mas não houve redução significativa das ectopias ventriculares. O tempo de condução inter-atrial correlacionou-se com o tamanho do átrio esquerdo. CONCLUSÃO: A metodologia mostrou-se adequada e segura, e poderá ser empregada na comparação de diferentes incisões atriais para exposição valvar mitral.

12.
Acta cir. bras ; 17(supl.3): 44-51, 2002. tab, graf
Artigo em Português | LILACS | ID: lil-335017

RESUMO

Introdução: O acesso cirúrgico por esternotomia mediana e atriotomia subseptal clássica pode, em certos casos, resultar em má exposição da valva mitral. Incisões atriais alternativas otimizam a exposiçao da valva mitral mas podem interferir na atividade elétrica atrial pós-operatória. Objetivo: Padronizar método para investigar a atividade elétrica atrial para emprego em estudos comparativos de diferentes atriotomias em cardiopatas submetidos á cirurgia cardíaca. Métodos: Análise com eletrocardiograma convencional e de 24 h (sistema Holter), pré e pós-operatória, e cardioestimulação epicárdica pós-operatória pelo método de Narula, em 10 pacientes submetidos à correção de valvopatias mitrais. resultados: No pré-op., os pacientes em ritmo sinusal apresentaram ectopias supraventriculares, com episódio de taquicardia supraventricular em 57 por cento dos casos, "flutter"atrial em 10 por cento e ritmo juncional em 10 por cento. todos apresentaram ectopias ventriculares, de baixa incidência em 70 por cento dos casos, e taquicardia ventricular não sustentada foi detectada em 30 por cento dos pacientes. No pós-operatório, houve 40 por cento de novas arritmias supraventriculares (fibrilação atrial, ritmo juncional, ritmo atrio baixo e taquicardia supraventricular paraxística), mas não ocorreram arritmias ventriculares. No pós-op. a função do nó sinusal não se alterou, ocorreu redução significativa das ectopias supraventriculares, com reversão de FApara ritmo sinusal em 1 paciente, mas não houve redução significativa das ectopias ventriculares. O tempo de condução inter-atrial correlacionou-se com o tamaho do átrio esquerdo. Conclusão: A metodologia mostrou-se adequada e segura, e poderá ser empregada na comparação de diferentes incisões atriais para exposição valvar mitral.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Valva Mitral , Ecocardiografia , Eletrocardiografia Ambulatorial , Estudos Prospectivos , Esterno
14.
Arq. bras. cardiol ; 63(3): 191-195, set. 1994. ilus, tab
Artigo em Português | LILACS | ID: lil-155549

RESUMO

PURPOSE--To verify the efficacy and safety of the creation of a barrier with radiofrequency (RF) in the tricuspid annulus and the vena cava ostium (TA-IVC). METHODS--Nine consecutive patients, 7 males, with age ranging from 36 to 76 years, with paroxysmal (7 patients) or permanent (2) type I atrial flutter (negative P wave in lead II, III and F) were submitted to RF ablation of TA-IVC istmo. One deflectable catheter with 4mm size tip was introduced into the right ventricle apex and pulled back to the inferior vena cava. When the atrial electrogram was detected the RF application was started. The RF was applied (20 watts during 60s) up to the proximity of inferior vena cava ostium. The end point was to stop atrial flutter. Then a vigorous atrial stimulation protocol, including isoproterenol infusion was used. In the next day, patients were submitted to transesophageal stimulation with the same protocol. RESULTS--Atrial flutter was interrupted in all patients (100//) with 4 to 28 (mean 16.7 +/- 7.7) applications. Eight patients (88.8//) with one session and 1 (11.1//) with two sessions. The mean time spent to stop the atrial flutter with one application was 30.5 +/- 18.5s. There were no complications. After a mean follow up of 3 +/- 1.6 month all patients (100//) are asymptomatic. Two of them are taking propranolol to control symptomatic atrial and ventricular ectopic beats. CONCLUSION--RF ablation of the TA-IVC istmo is efficient and safe in a short term follow up to interrupt and prevent re-induction and recurrence of type I atrial flutter


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Flutter Atrial/cirurgia , Ablação por Cateter
15.
Arq. bras. cardiol ; 63(2): 111-5, ago. 1994. ilus
Artigo em Português | LILACS | ID: lil-156019

RESUMO

We describe three cases of the pseudo-pacemaker syndrome. One of them due to selective fast pathway fulguration of atrioventricular nodal reentrant tachycardia and two others have occurred in spontaneous form. All cases were related with the presence of first-degree atrioventricular block and sinus node tachycardia. The treatment was done with complete atrioventricular block induction catheter ablation and permanent pacemaker implantation in two patients. In conclusion, the procedure of radiofrequency ablation to control AV nodal reentry tachycardia must preserve the fast nodal pathway in order to avoid the pseudo-pacemaker syndrome and this syndrome can spontaneously occur and must be considered during investigation of etiology of syncope


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Marca-Passo Artificial , Ablação por Cateter/efeitos adversos , Complicações Pós-Operatórias/etiologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/terapia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/terapia , Síncope/diagnóstico , Síncope/etiologia , Síncope/terapia